Air Consumption Table
Qn: Air consumption of a cylinder actuator (l / min)
QA: Air consumption cylinder reciprocating actuator of a (l / min)
QB: Air consumption of piping (solenoid valve to the cylinder room) (l / min)
A 1: Push the pressure receiving area (CM 2)
A 2: Pull-in of the pressure receiving area (CM 2)
A 3: Inner diameter of the pipe (CM 2)
L: The cylinder stroke (CM)
LH: Pipe length (CM)
P: Operating pressure (kgf / CM 2)
n: Operating frequency (kgf / CM 2)
Bore ( mm ) | 10 | 12 | 16 | 20 | 25 | 32 | 40 | 50 | 63 | 80 | 100 | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Shaft ( mm ) | 6 | 6 | 6 | 8 | 10 | 12 | 16 | 20 | 20 | 25 | 25 | |
Pressure area cm 2 Operating pressure kgf / cm 2 |
A 1 | 0.80 | 1.10 | 2.0 | 3.1 | 4.9 | 8.0 | 12.3 | 16.6 | 31.2 | 50.20 | 78.50 |
A 2 | 0.50 | 0.90 | 1.7 | 2.6 | 1.0 | 6.9 | 10.6 | 16.5 | 28.0 | 45.30 | 73.60 | |
1 | 0.03 | 0.04 | 0.1 | 0.1 | 0.2 | 0.3 | 0.50 | 0.70 | 1.20 | 1.90 | 3.00 | |
2 | 0.04 | 0.06 | 0.1 | 0.2 | 0.3 | 0.4 | 0.70 | 1.10 | 1.80 | 2.90 | 4.60 | |
3 | 0.05 | 0.08 | 0.2 | 0.2 | 0.4 | 0.6 | 0.90 | 1.40 | 2.40 | 3.80 | 6.10 | |
4 | 0.06 | 0.10 | 0.2 | 0.3 | 0.5 | 0.7 | 1.20 | 1.80 | 3.00 | 4.80 | 7.10 | |
5 | 0.08 | 0.12 | 0.2 | 0.3 | 0.6 | 0.9 | 1.40 | 2.20 | 3.60 | 5.70 | 9.10 | |
6 | 0.09 | 0.14 | 0.3 | 0.4 | 0.6 | 1.0 | 1.60 | 2.50 | 4.10 | 6.70 | 10.60 | |
7 | 0.10 | 0.20 | 0.3 | 0.5 | 0.7 | 1.2 | 1.80 | 2.90 | 4.70 | 7.60 | 12.20 | |
8 | 0.12 | 0.20 | 0.3 | 0.5 | 0.8 | 1.3 | 2.10 | 3.30 | 5.30 | 8.60 | 13.70 | |
9 | 0.13 | 0.20 | 0.4 | 0.6 | 0.9 | 1.5 | 2.30 | 3.60 | 5.90 | 9.60 | 15.20 |