PK6524 Intuitive setting of pressure sensor
Dimensions
Specifications
Application | ||
Application | Used in industrial applications | |
Medium | Liquid and gaseous media | |
Medium temperature [ °C ] | -25 ... 80 | |
Compressive strength | 25 bar | 362 psi |
Minimum burst pressure | 300 bar | 4350 psi |
Pressure | Relative pressure | |
Maximum allowable working pressure ( Applicable to the CRN standard ) |
25 bar | 362 psi |
Electrical data | ||
Operating Voltage [ V ] | 9.6 ... 32 DC | |
Current consumption [ mA ] | < 25 | |
Minimum insulation resistance [ MΩ ] | 100; ( 500 V DC ) | |
Protection level | III | |
Reverse protection | Yes | |
Total input / output | ||
Total number of inputs and outputs | Number of digital outputs: 2 | |
Output | ||
Number of outputs | 2 | |
Output signal switch | signal | |
Electrical design | PNP | |
Number of digital outputs | 2 | |
Output function | NC + NO | |
Maximum switching output DC voltage drop [ V ] | 2 | |
Continuous current load of switching output DC [ mA ] | 500 | |
On-off level DC [ Hz ] | 100 | |
Short circuit protection | Yes | |
Short circuit protection type | Pulse | |
Overload protection | Yes | |
Measurement / setting range | ||
Measuring range | 0 ... 10 bar | 0 ... 145 psi |
Switch poin, SP | 0.5 ... 10 bar | 7.5 ... 145 psi |
Recovery point, rP | 0.3 ... 9.8 bar | 5 ... 142 psi |
Accuracy / deviation | ||
Switch point accuracy [ % of final value ] | < ± 2,5; ( Adjustment accuracy ) | |
Repeatability [ % of final valu e] | < ± 0,5; ( temperature fluctuatio < 10 K ) | |
Characteristic curve deviation [ % of final value ] | < ± 1,5 ( BFS L) / < ± 2,5 ( LS ); ( BFSL = Best Fit Straight Line; LS = limit point setting ) |
|
Temperature drift per | < ± 0,5 | |
Temperature drift per | < ± 0.5 | |
Software / programming | ||
Switch point adjustment | Swivel | |
Working conditions | ||
Ambient temperature [ °C ] | -25 ... 80 | |
Storage temperature [ °C ] | -40 ... 100 | |
Enclosure protection grade | IP 67 | |
Certification / testing | ||
EMC electromagnetic compatibility | DIN EN 61000-6-2 | |
DIN EN 61000-6-3 | ||
Impact resistance | DIN EN 60068-2-27 | 50 g ( 11 ms ) |
Seismic | DIN EN 60068-2-6 | 20 g ( 10...2000 Hz ) |
MTTF [ year ] | 500 | |
Pressure Equipment Directive | Good engineering practice; can be applied to group 2 fluids; liquids of fluid group 1 according to demand | |
Mechanical technical data | ||
Weight [ g ] | 91.8 | |
Material | PBT; PC; FKM; stainless steel ( 1.4404 / 316 L ) | |
Material ( wet parts ) | stainless steel ( 1.4404 / 316 L ); FKM | |
Minimum pressure cycle | Fifty million | |
Tightening torque [ Nm ] | 25 | |
Process connection | Threaded connection G 1/4 External thread Internal thread M5 | |
Display / operator | ||
Display | Operation | LED, green |
Switch status | LED, yellow | |
With scale | Yes | |
Comment | ||
Packing unit | 1 piece | |
Electrical connections | ||
Connector | 1 x M12 |