Parts And Accessories

PME Times Slight Adjustable Pressure Switch

Feature

  • This series of times for small membrane-type pressure switches often use the pressure of the hydraulic / hydraulic / pneumatic / oil lubrication system of control, the body is hexagonal, the use of NBR rubber anti-oil film, silver contacts, and have attached the cable clamp terminals balance spring. Loosen the junction box cover screws, open GAPS junction box cover, you can see the adjustment screw, turn the adjustment screw to adjust the pressure of spring work must be careful not to adjust the image. Pressure switch is set to follow the needs of the customer. NO or NC contacts as a condition of no pressure, we recommend using the junction box cover CAP3 terminal and internal components in order to avoid moisture or dust that is affected.

Ordering Code

Specification

MODEL ADJUSTMENT
RELATIVE
PRESSURE
RANGE
bar
DIMENSIONS
“A” mm
MAX. STATIC
PRESSURE
bar
FIXED
HYSTERESIS
AT 25°C
bar
TOLERANCE
AT 25°C
bar
EXECUTION
VERSION FOR CAP
1
VERSION FOR CAP
3
BRASS
BODY
EXECUTION
ZINC
PLATED
BODY
EXECUTION
BODY
EXECUTION
PME 1 0,1 - 1 40 46 300 300 300 0,1 ±0,1 Diaphragm
PME 2 0,15 - 2 40 46 300 300 300 0,15 ±0,2
PME 10 2 - 10 40 46 300 300 300 0,2 ±0,3
PME 20 10 - 20 40 46 300 300 300 0,3 ±0,4
PME 50 20 - 50 40 46 300 300 300 0,8 ±1
PME 80 50 - 80 40 46 300 300 300 5,5 ±2
PME 150 50 - 150 40 46   300 300 10 ±5 Steel piston
PME 250 100 - 250 40 46   600 600 15 ±10
PME 300 50 - 300 42 49   600 600 20 ±15

Online Inquiry